Table of Contents


NAME

data:transient - find slew-rate and settling time from transient signal (Decida Procedure)

USAGE

          data:transient d signal slew_rate settling_time args

ARGUMENTS

d Decida data object.
signal Transient output signal
slew_rate Name of return variable for slew-rate
settling_time Name of return variable for settling_time
args OPTIONS

OPTIONS

-time <time_column> Specify the time column in the data object. (default is TIME)
-slew_pct Specify the percentage of the initial to final transient level for measuring slew. (default is slew_pct=40: 40% to 60%)
-settle_pct Specify the percentage of the initial to final transient level to bracket the settling. (default is 1%)

RESULTS

Return slew rate, and settling time in slew_rate, settling_time variables.
Return 1 for successful slew-rate measurement

NOTES

Assumes that initial and final signal values are settled.

AUTHOR

Richard Booth

Table of Contents